Diesel-Driven Oil-Injected Air Compressor

FOOENS Diesel-Driven Oil-Injected Air Compressor uses a CAT engine core and integrates a container protective frame, supporting operation in harsh outdoor environments. It covers a working pressure range of 12-25bar(e) and flow requirements of 21.5-27.7m³/min, making it suitable for high-pressure air supply in off-grid scenarios such as mining and oil & gas.
Model | XAHS836 | XRHS836 | XRVS476 |
---|---|---|---|
General Parameters | |||
Dimensions L×W×H (mm) | 4,908×2,140×2,479 | 4,908×2,140×2,479 | 4,908×2,140×2,479 |
Mass-dry/wet (kg) | 4,331/4,778 | 4,331/4,778 | 5,380/5,700 |
Fuel Tank Capacity (L) | 570 | 570 | 796 |
Sound Pressure Level LPA (7 meters) | 76 dB(A) | 76 dB(A) | 76 dB(A) |
Air Outlet(in) | G2 | G2 | G2 |
Engine | |||
Engine Brand | CAT | CAT | CAT |
Engine Model | C9 ATAAC | C9 ATAAC | C13 Acert T3 |
Output Power (kW) | 224 | 224 | 328 |
Performance Parameters | |||
Compression Stages | 1 | 1 | 2 |
Max Displacement Flow (m³/min) | 23.9 | 21.5 | 27.7 |
Max Working Pressure (bar(e)) | 12 | 20 | 25 |
Special Features | |||
Integrated Aftercooler | — | — | Standard Configuration |
Spill Containment Frame | — | — | Standard Configuration |
Spark Arrestor | — | — | Standard Configuration |
Overspeed Shutdown System | — | — | Standard Configuration |
1. Oil Quantity Standard: Full oil quantity = Oil tank capacity × 0.95
2. Special configuration models come with standard CAT original safety components
3. Sound pressure level test distance is within 7 meters around the equipment
Features
- Powered by CAT C9/C13 engine (224–328 kW), no external power required, suitable for remote areas and mobile operations
- Container-type weatherproof design with built-in spark arrestor and overspeed shutdown system ensures safe field operation
- Sound pressure level at 7 meters is only 76 dB(A), reducing noise disturbance in sensitive areas
Advantages
- The XRVS476 model delivers a flow rate of up to 27.7 m³/min, with a 796L fuel tank for extended continuous operation
- Equipped with a spill-proof frame and spark arrestor, fully compatible with flammable and explosive environments such as oilfields and mining sites
- Standardized frame size (4,908×2,140×2,479 mm) and G2 interface ensure plug-and-play deployment